    Brand Name : Anchorwill
    Model Number : Ck60
    Certification : 3C
    Payment Terms : L/C, T/T
    Delivery Time : 1 - 10
    • Product Details
    • Company Profile

    2.2 Kw 3kw 200kw 250 Kw 400kw Soft Starter with Built-In Bypass Protection and Monitoring Short-Circuit

    Ball Mill Soft Starter Ck60 Built-In Bypass Soft Starter
    product description

    By limiting the starting current and starting torque, the soft starter is able to reliably prevent mechanical shock and grid voltage drop during starting. By controlling the conduction angle of the thyristor, the motor starting voltage is reduced and raised to the rated voltage within the set starting time. With this stepless control of the motor voltage, the motor can be regulated according to the load characteristics of the driven machine, gently accelerating the mechanical equipment.

    This significantly improves the operating performance of mechanical equipment, reduces maintenance costs and extends service life.


    Widely used in water supply pumps, ventilation systems, air-conditioning refrigeration station circulating pumps in water conservancy, mines, factories, high-rise buildings, large shopping malls and other places,

    Fire-fighting and sprinkler pump control, etc.


    ItemProject Description
    Applicable standardsGB14048.6-2016(IEC947-4-2)
    Applicable motor typeSquirrel-cage three-phase asynchronous motors
    Motor power11A……1260A(5.5~630kW)
    Control VoltageAC220V±15%;50Hz/60Hz;AC110V±15%
    inputRated VoltageAC380V±15%;50Hz/60Hz;660V±15%
    Adjustable start time1~120s adjustable
    Adjustable stopping time0~120s adjustable
    control mode1.Ramp voltage 2.Ramp current 3.Current limit mode
    I/0Logic Inputs3 way(X1~X3)
    Analog Outputs1 channel 4~20mA/0~10V
    Relay outputs2 relay outputs
    Run command inputsKeyboard display unit given, control terminal given
    RS485 communication given
    CommunicationIntegrated communication protocolsStandard Modbus protocol, 1 channel
    Display UnitLCD displayCan display current, voltage, alarm and other motor parameters
    Protection and monitoringShort-circuit, over-voltage, overload, under-voltage, phase loss, over-current, temperature protection
    matrixLocationIndoor, not subject to direct sunlight, no dust, corrosive, flammable gases, oil mist,
    water vapor, dripping water or salt, etc.
    altitudeAltitude more than 1000m, the capacity should be reduced accordingly, every increase of 100m, the current is reduced.
    Environmental humidity-10℃~+40℃; -40℃ or above shall be used at a reduced capacity.
    Above 40℃ shall be used at reduced capacity
    For every 1℃, the current shall be reduced by 2%.
    TemperatureLess than 95%RH, no water droplet condensation.
    VibrationLess than 5 .9m/s2(0 .6g)
    Storage Temperature-40℃~70℃
    frameworkProtection classIp20
    Cooling methodRadiator, natural cooling
    InstallationVertical installation in cabinet

    Note:
    CK60 built-in bypass economic soft starter adopts two start-stop control methods: panel giving and control terminal (two-wire and three-wire) giving.
    1. Two-wire control is hold signal, three-wire control is trigger signal.
    2. When two-wire control is adopted, panel control is invalid.
    3. When three-wire control is used, panel control is effective.
    4. When panel control is adopted, X3 and COM must be kept closed.
    5. External button signal should be kept >200ms to be valid, <200ms to be invalid.